ASTM C1363 PDF

This standard is issued under the fixed designation C ; the number immediately 1 This test method is under the jurisdiction of ASTM Committee C- 16 on. ASTM C () Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus. Annual. Our calibrated hot box is one of the largest in the country accepting test assemblies up to 9’x16′. Its design allows any orientation from fully vertical to fully .

Author: Voodoole Meztimi
Country: Chile
Language: English (Spanish)
Genre: Finance
Published (Last): 2 May 2005
Pages: 257
PDF File Size: 15.87 Mb
ePub File Size: 3.42 Mb
ISBN: 917-9-55255-212-8
Downloads: 63588
Price: Free* [*Free Regsitration Required]
Uploader: Mazusho

Whatever the test orientation, the apparatus performance shall first be verified at that orientation with a specimen of known thermal resistance in place.

ASTM C1363

Note that the use of Test Method C or similar apparatus creates additional uncertainty since those devices are calibrated using transfer standards or standard reference materials. Consider the typical residential wall, which consists of a wood frame with fiberglass insulation between the studs, sheathing, a weather resistive barrier, drywall on the interior walls, and exterior siding.

The direction of airflow motion under forced convective conditions shall be either perpendicular or parallel to the surface. The general testing procedures for these cases are described in Annex A The equipment performing these measurements requires calibration to ensure that asmt data are accurate. Practice C may be used as a guide for test specimen conditioning. Please enter your email address.

These panels, or representative sections of the panels, have had their thermal performance measured on other devices that are asfm traceable or have been favorably compared to a national standards laboratory. As such, the hot box is considered a primary method and the uncertainty of the result is analyzed by direct evaluation of the component measurement uncertainties of the instrumentation used in making the measurements.

  FREE NYSSMA MANUAL PDF

Home Innovation ASTM C Hot Box | Home Innovation Research Labs

However, larger hot boxes have been used to characterize projecting skylights and attic sections. The key to an accurate result is correctly measuring the heat input to the hot side and ensuring that all the heat goes from the hot side to the cold side and that none either leaks out of the Hot Box or bypasses the test specimen. We have no amendments or corrections for this standard. Auditing Consulting Sourcing Training. Air infiltration or moisture migration can alter the net heat transfer.

It’s easy to model one-dimensional conductive heat flow, but modeling three-dimensional heat transfer is much more difficult and less reliable. The general testing procedures for these cases are described in Annex A The general principles of the hot box method can be used to construct an apparatus to measure the heat flow through industrial systems at elevated temperatures.

Additional characterization is required to insure that c136 aspects of the heat flow and storage are accounted for during axtm test. In this type of testing, bigger is definitely better.

Finally, heat flow in this scenario is a three-dimensional phenomenon. This method is also used to measure the thermal performance of a building material at standardized test conditions such as those required in material Specifications CCC and Practice C By performing this benchmarking process, the hot box operator is able to develop the additional equations that predict the magnitude of the corrections to the net heat flow through the specimen that account for any hot box wall loss and flanking loss.

Historical Version s – view previous versions of standard.

Other orientations are also permitted. The report shall contain a warning stating that the use of the barriers might modify the heat transfer c11363 the system causing significant errors. By performing this benchmarking process, the hot box operator is able to develop the additional equations that predict the magnitude of the corrections to the net heat flow through the specimen that account for any hot box wall loss and d1363 loss.

  ELVIAL 6700 PDF

Detailed design of that type of apparatus is beyond the scope of this method.

Certification Formally confirming that your products and services meet all trusted external and internal standards. This standard is also available to be included in Standards Subscriptions.

Add to Alert PDF. When constructed to measure c13633 transfer in the vertical direction, the hot box is used for testing roof, ceiling, floor, and other horizontal structures. Need help or have a question? For the results to be representative of a building construction, only representative sections shall be tested.

Direct current DC power is used to power both the heater and the fans as DC current provides a more accurate measurement of the power input. During initial setup and periodic verification testing, each measurement system and sensor is calibrated against a standard traceable to a national standards laboratory. The box has a heat flow meter consisting of two thermopiles built into its walls.

For more information on our thermal testing capabilities xstm here. Assurance Testing Inspection Certification. Through our network of over 43, people in 1, laboratories and offices in countries, Intertek provides quality and safety solutions to c3163 wide range of industries aastm the world.